If you cut the ends off the. Please hit that subscribe button if y. 3 wire cords are used when the receptacle is an existing 3 prong type and does not contain an equipment ground wire. The 12' extension cord I'm using is 10 gauge, 3-conductor. Basically, you install a regular outlet near the projector, and run the approriate size Romex to a . You could use this dryer cord and the adapter for the plug on the saw. I used Romex wire to extend my plug by adding an additional wall plug where I only use 1 plug at a time. $24.99 $ 24. Extension cords must be stranded wire. I think it is cheaper adding another plug than building an extension cord. 400.8 Uses Not Permitted (ref. By code you can load a 20 amp ckt up too 16 amps and a 15 amp ckt up to 12 amps. #7. Use cable ties. It's all about the wire size and type. Step 4 First determine maximum load you will add to the circuit, how . It typically costs around $1.50 per foot. . Received 147 Votes on 130 Posts. Connect the furnace hot wire to the common (dark) terminal of the 3 way switch. Connect the hot wire from the panel to the other traveler terminal of the switch. Because it is not very flexible, it is not generally used for extension cords, but it can be. Remove the paper covering the bare wires. Can NM-cable (Romex) be used to make a cord and plug to connect an appliance? I'm thinking of running 100 ft to my shed for lighting, bench grinder . One of our rigs has a 25-foot shore power cord, so building an additional 25 feet of extension cord would require figuring a full 50-foot run. Use the correct gauge wire for the load you plan to service with the cord. The "guy installing a surround sound system" did not make an extension cord. . Answer (1 of 4): Yes, you can. What that number means is 14 gauge (wire size), 2 conductor which also includes a bare ground wire. Use a pencil to mark the anchor points on the wall. Step 2. If the wires won't reach, or something else, just get an additional junction box, nail it to an open stud where the wires will reach, then get an additional run of romex to run from there to where you can reach an available . The GFI is a good idea. just like with trailers, its always best to go bigger then you think you need. 5% coupon applied at checkout Save 5% with coupon. You can plug 2 extension cords in one outlet but with a risk of overloading. If you are close to the 15 amps you might look into buying a 10-3 extension cord. Trying to figure out new ideas for youtube channel.What are you interested to watch from my youtube channel on youtube. Get it as soon as Wed, Dec 22. Personally, I would just disconnect the extension cord and wire the romex run going to the ceiling back into another box. Nice welder it would be a shame to screw it up or burn down your place! The smaller the gauge Number the larger the conductor size. Extension Cord) Flexible cords and cables shall not be used for the following: (1) As a substitute for the fixed wiring of a structure. With a splicing tool, remove approximately 1/2 inch of the plastic coating from the white and black wires. Hook them up like this: Green jacket Green terminal. Along with the romex buy 200+ (or the length required) of 3/4" PVC conduit. Use an ordinary but grounded extension cord to connect the inlet to the generator when needed. Brett 6 AWG is a little overkill, but it'll work great. You are not allowed to make extension cords from Romex - you must use stranded wire. When you insert the plug (connected to Romex) into the receptacle, it energizes the Romex run to the ceiling fan. inlet. 4.9 out of 5 stars 24. Ensure at least 5-6 inches of the cord through the housings of the new plugs. For 120V welders, this 10-gauge cord handles 20-amps out to 50 feet. - Tungsten Wizard. We also allowed for up to a 5% voltage dropwhich some people might consider too high. You are guaranteed to have the right sized wire. Mark anchor points. . Yeah, building wiring (like Romex) is exclusively designed to go inside walls. If you cut the ends off the. If you are going to extend a circuit, do it right. Extension cords are built for convenience but also built for temporary use. $12.99 $ 12. Feb 4, 2009. Received 147 Votes on 130 Posts. I have also seen some situations where people use a "romex extension cord" through the wall for there . This is in reference to your memorandum of June 12, 1991 to your area directors and district supervisors on the subject of extension cords acceptable for use (copy attached). Mar 6, 2020 at 3:43. use 1" pvc electrical conduit (3/4" is too tight to feed the wire) and use the long sweeping 90s for it at the end to come up. Romex can only be used for in-wall wiring. When you purchase an extension cord, that cord has been designed and tested to operate properly under certain circumstances. If you look at the terminals on the replacement connector, one will have a brass (gold) colored screw, one screw will be nickel (silver) and the final one will be green. Is that because one is a solid wire and the other a stranded wire? 3 wire cords are used when the receptacle is an existing 3 prong type and does not contain an equipment ground wire. One end has NEMA 6-50R receptacle. Romex is NOT cord. If you decide to build your own, always double-check your connections before putting your cord into service. Slide the new male and female plugs onto the cord. That's good for at least 30 feet in length (which when added to your shore cord probably makes a 50-60 foot total run). #12. 2) Dryer cords come in 2 configurations, either 3 wire or 4 wire. For our extension cord size chart calculations, we assumed 120V single phase with a power factor of 1. We believe your interpretation is unduly restrictive and that it does not accurately reflect the requirements of the . to an attachment plug or, as an appliance coupler, to an equipment. If you . here is some links to Lowes for the plugs. While durable, a PVC cover loses . Further, plugs and sockets are NOT rated for solid-core wire, so cannot be put on Romex. With cable jackets having a "W" code rating, both are suitable for outdoor use. Also note that cordage counts every wire - so 10/3 SO is actually only black white . All though there is multistrand romex look at that compared to a UL listed 12/3 extension cord and there are about x2 the strands. Cut the base and cord cover to match the length you just measured. It isn't designed to withstand repeated flexing (as in an extension cord) -- it usually isn't stranded, and if it is, the insulation is not designed for constant abrasion against the conductors. (2) Where run through holes in walls, structural ceilings, suspended ceilings, dropped ceilings, or floors. In every instance, the connector failed to hold on to the romex well enough. The wires in an extension cord are likely to be 16 gauge or thicker, and that should work well enough for most speakers. Cords count the ground wire, Romex does not. Put the romex in the conduit. Cord / cable. Go take a look at any large commercial building that is running single phase a/c's, coolers, exhaust fans, etc.. and you'll find 100' plus runs all over the place. One of the test was to hang a weight from the cord, to see if the connector did actually prevent the strain from being transmitted to where the wires were connected. Not the prettiest, but it will work. . Max 20 feet long. Add up all of the lights amperage values as listed and do not go above the above values. I personally think that extension cord wire is actually alot better then romex type wire. Hey Gang! Some audiophiles will surely disagree, but I would feel comfortable using almost any insulated wire for my speakers. Originally Posted by nativenewenglander Get a 100 feet of 12 guage romex and make an extension cord. Quote: @CasualJoe I can use a Romex on the plug end. Step 3. Run the dryer cord and the longer 'extension cord' wire into a square metal junction box, twist and wirenut, then a cover on the box. Paint. #10 Romex is not. Buy 1- 250' roll of 12/2 wg romex, use it for your extension cord. Remember that extension cords are made to be moved around and stepped on and even ran over with equipment in some circumstances. Measure the wall to determine the length of the cords you want to cover. If you do buy a heavy duty #12 extension cord. Long Extension Cord 15 Ft, NTONPOWER Thin Flat Extension Cord Under Carpet, Rug, Door, 3 Outlets Power Strip with 2 USB Ports, Wall Mount Desktop Charging Station for Home Office, Black. I don't have a clue what you are asking. . Connect the inlet hot terminal to one traveler (bright) terminal of the switch. Don Helgeson , former Chicago Movie Operator (1966-2003) I did test several such connectors on Romex, rather than 'extension cord' material. It's would run about three feet from one gang box behind a mounted TV to another gang box towards the floor that would be next to a receptacle. Take the split ends and pull the outer sheath apart to reveal the individual wires inside. THHN (the right extension cord would work) in 1/2" PVC is the way to go. Nov 30, 2000 6,504 276 126 . But the "T" designation on their jackets shows a thermoplastic (PVC) cover. (3) Where run through doorways, windows, or similar openings. Answer (1 of 4): Yes, you can. Location: Henly, Texas. DEWENWILS 1 FT 12/3 Gauge Indoor/Outdoor Extension Cord with LED Lighted End, STW 15 Amp/125V/1875W Yellow Outer Jacket Contractor Grade Heavy Duty Power Cable with Grounded Plug, ETL Listed. You need actual cordage, which starts with an S, and has O, sometimes J and sometimes W. Such as SO, SJOOW etc. We also utilized the 2014 NEC Chapter 9, Table 9 numbers for impedance and voltage drop calculations. Once you modify the cord in any way, you've voided any listing or labeling on the cord (UL listing, etc.). I did test several such connectors on Romex, rather than 'extension cord' material. Quote: @CasualJoe I can use a Romex on the plug end. 2) Dryer cords come in 2 configurations, either 3 wire or 4 wire. three #6 conductors and one #8 ground wire. The solid copper core in Romex WILL fail, potentially causing arcing and fires, because solid core wire WILL fracture when used as an extension cord. Cut. The wires in an extension cord are likely to be 16 gauge or thicker, and that should work well enough for most speakers. Yes, you can make a long extension cord using #12 wire meant to be buried and leave it above ground during the winter. A standard 50A extension cord should be 6/3 + 8/1, i.e. dandersen (David Andersen, TN HI# 40) February 28, 2007, 3:48pm #5 Use conduit, run the appropriate sized wires and exterior weather-proof/ water-proof box and GFCI receptacle. Conceal with flex tubing. When running any electrical extension cord device always make sure to check the tag and see that it is UL listed, also check the label on the cord to see the extension cord is able to handle the amperage of the appliance it is connected to. Oddometer: 378. Can a dehumidifier be plugged into an extension cord? A female contact device to be wired on flexible cord. The problem, as OP suggested, is the listing of the plug / connector. Whatever you do, don't skimp on the wire gauge or the fittings. Lay the cables. And, here's a good-quality 25-foot extension cord for small 240V welders. extension cord from an overhead box outlet to the bench. That cable is allowed to be run through walls, run concealed, through floors exposed (if 334.15), allowed to be fished, etc. So when your needing a three conductor cable to wire up a basic 2-way switch, you will need a 14/2 w/ground cable. The problem with extension cords is that they are not listed, labeled, or rated for long-term use. for use as an extension from an outlet to make a detachable electrical connection. One of the test was to hang a weight from the cord, to see if the connector did actually prevent the strain from being transmitted to where the wires were connected. paperfist Diamond Member. Step 3 When you return home, take one end of the 10/3 SJ-cord and make a small slice in it with your knife. Make sure it is wired with #12 wire. Some audiophiles will surely disagree, but I would feel comfortable using almost any insulated wire for my speakers. The opposite end plugs into my generator's 240 volt outlet. Wednesday, July 4, 2018. The extension cord is also only rated for 15 amps at 12 gauge vrs 20 amp for Romex at 12 gauge. The answer is no, and the principle behind it is simple: the electrical cords that manufacturers use for appliances, like the one shown above, have multiple strands in each wire that will flex repeatedly without breaking, but an NM-cable . . Can I use Romex to make an extension cord? Dont run any wire underground with a paper insulation inside of it. Can NM-cable (Romex) be used to make a cord and plug to connect an appliance? That company was taken over by Southwire, and today ROMEX is a trademark name, like Kleenex. Hi,when the power goes out in my house i connect my 30 amp generator to an dryer outlet with 8/4 15 feet extension cord,but i would like to run my generator from my shed wich is 100 fett away,what typ read more Make sure the wires are separated underneath. Whatever you do, don't skimp on the wire gauge or the fittings. do what you are thinking about. Extension cord length - House -remodeling, decorating, construction, energy use, kitchen, bathroom, bedroom, building, rooms - Page 3 - City-Data Forum Expose about an inch and a half of the inside wires. Extension cords are not rated for direct burial, and are not meant for long term exposure to the elements. DIY extension cord with Romex I know that it's against code to run an extension cord behind a wall but is it acceptable to create my own using Romex cable to do so. UF cable 18" below grade will do. If you don't have at least that don't worry about an extension cord! Then you can put it away for the spring, summer . The projector Power Cable will connect to the extension cord above one of the tiles. While researching them I just noticed the different way they label Romex and extension cords and it made me curious as to why. Do not use Romex as an extension cord, however. The outlet box is on a 15A breaker, and the extension cord is rated for 15A and is 25 feet long with 12 gauge wire. In other words the Romex has been converted into an extension core with a ceiling fan on one end and a plug on the other end. Wednesday, July 4, 2018. Apr 16, 2012. If you decide to build your own, always double-check your connections before putting your cord into service. The answer is no, and the principle behind it is simple: the electrical cords that manufacturers use for appliances, like the one shown above, have multiple strands in each wire that will flex repeatedly without breaking, but an NM-cable . You'll need enough cable between the plugs to work on the inner wires safely. 3) If the receptacle will be a new installation, per code it needs to be a 4 prong receptacle and the circuit needs to be a 4 wire circuit using 2 hots, 1 neutral . Different options for the wiring and repair of a damaged extension cord. They are meant for temporary use. SUBJECT: Acceptable Job-Made Extension Cords. So at the stove outlet it would be plug --> 8/2 Romex --> Junction box in attic --> connect with SE cable --> terminates into an outlet in the wall where welder can be plugged in. The Uniform Fire Code states that these types of cords are intended for the temporary and immediate use of an appliance and are not to be permanently "installed". Everything I've read online says Extension cords are to be used as a temporary measurement, mostly due to tripping hazzards. Most 120Vac household circuits are fine using a 12 or 14 gauge wire. And since you won't use Romex, you'll need a 10-3 SJOOW service cord, also easily available at Home Depot and the like. Call an electrician and have some outlets added in your garage. It should say on the romex. 4.2 out of 5 stars 45. In every instance, the connector failed to hold on to the romex well enough. 99. The christmas lights that I use have a amp rating on the cord itself. In this video we show you how to wire up your bro. He did make an extension cable. Cord / cable. 1. Mount base. There'll be no big draws at the bench, maybe a light, hand drill, (A 10-3 cord = 10-2 Romex for wires inside). I don't have a clue what you are asking. So at the stove outlet it would be plug --> 8/2 Romex --> Junction box in attic --> connect with SE cable --> terminates into an outlet in the wall where welder can be plugged in. If there is ever a fire, this could be a factor (but that's a legal issue, and outside the scope of the site). 99. One of our rigs has a 25-foot shore power cord, so building an additional 25 feet of extension cord would require figuring a full 50-foot run. Your individual wires, after the outside jacket is trimmed back, should be black (or red), white and green. We hope everyone had a Happy Thanksgiving Extension Cord companies aren't gonna like this one! 3) If the receptacle will be a new installation, per code it needs to be a 4 prong receptacle and the circuit needs to be a 4 wire circuit using 2 hots, 1 neutral . It looks like normal Romex (type NM) house-wiring cable, but it's solid plastic extruded around the wires - not a hollow sleeve with paper filler. Step 3: Plug in Extension Cords. Separate the male connector by unscrewing the screws holding it together. I think HD has #8 SO cable that you can cut to length, but not sure. At the bench I'll terminate the extension cord to a 5 outlet power strip with surge protector.